The Schneider Electric LC1F500M7 TeSys F Contactor is a robust and high-capacity switching device designed for controlling electric motors and power circuits. With three poles, three normally open (NO) contacts, and a 500 A AC3 rated current at 440 V, this contactor is suitable for a wide range of industrial applications. The 220 V AC coil ensures precise and efficient operation.
Key Features:
High-Performance Contactor: Schneider Electric's LC1F500M7 TeSys F Contactor is built for heavy-duty tasks, making it ideal for challenging industrial environments.
Three Normally Open Contacts: This contactor offers three NO contacts, enhancing its versatility in controlling motors and equipment.
Reliable and Durable: Schneider Electric is known for producing high-quality and dependable electrical components, ensuring the longevity and efficiency of this contactor.
Wide Range of Applications: The 500 A AC3 rated current makes it suitable for various industrial settings.
Technical Specifications:
Pole Configuration: 3P (Three Poles)
Rated Current AC3: 500 A
Net weight: 11.35 kg
Rated Operational Voltage AC3: 440 V
Coil Voltage: 220 V AC
Specifications | |
Main |
|
Range | TeSys |
Range of product | TeSys F |
Product or component type | Contactor |
Device short name | LC1F |
contactor application | Motor control |
Resistive load | |
utilisation category | AC-1 |
AC-4 | |
AC-3 | |
Poles description | 3P |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz |
<= 460 V DC | |
[Uc] control circuit voltage | 220 V AC 40...400 Hz |
[Ie] rated operational current | 700 A (at <40 °C) at <= 440 V AC AC-1 |
500 A (at <55 °C) at <= 440 V AC AC-3 | |
Complementary | |
[Uimp] rated impulse withstand voltage | 8 kV |
[Ith] conventional free air thermal current | 700 A (at 40 °C) |
Rated breaking capacity | 4000 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 4200 A 40 °C - 10 s |
3200 A 40 °C - 30 s | |
2400 A 40 °C - 1 min | |
1500 A 40 °C - 3 min | |
1200 A 40 °C - 10 min | |
Associated fuse rating | 500 A aM at <= 440 V |
800 A gG at <= 440 V | |
Average impedance | 0.18 mOhm - Ith 700 A 50 Hz |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 |
1500 V conforming to VDE 0110 group C | |
Power dissipation per pole | 88 W AC-1 |
45 W AC-3 | |
Overvoltage category | III |
power pole contact composition | 3 NO |
Motor power kW | 250 kW at 380...400 V AC 50/60 Hz (AC-3) |
280 kW at 415 V AC 50/60 Hz (AC-3) | |
295 kW at 440 V AC 50/60 Hz (AC-3) | |
355 kW at 500 V AC 50/60 Hz (AC-3) | |
335 kW at 660...690 V AC 50/60 Hz (AC-3) | |
335 kW at 1000 V AC 50/60 Hz (AC-3) | |
147 kW at 220...230 V AC 50/60 Hz (AC-3) | |
80 kW at 400 V AC 50/60 Hz (AC-4) | |
Control circuit voltage limits | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) |
Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C) | |
Mechanical durability | 10 Mcycles |
Inrush power in VA | 1100 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
Hold-in power consumption in VA | 18 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
Maximum operating rate | 2400 cyc/h 55 °C |
Operating time | 40...65 ms closing |
100...170 ms opening | |
Connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end |
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end | |
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end | |
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end | |
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end | |
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end | |
Power circuit: bar 2 cable(s) - busbar cross section: 40 x 5 mm | |
Power circuit: lugs-ring terminals 2 cable(s) 240 mm² | |
Power circuit: bolted connection | |
Tightening torque | Control circuit: 1.2 N.m |
Power circuit: 35 N.m | |
mounting support | Plate |
Heat dissipation | 18 W |
motor power range | 250…500 kW at 380…440 V 3 phases |
110…220 kW at 380…440 V 3 phases | |
110…220 kW at 200…240 V 3 phases | |
250…500 kW at 480…500 V 3 phases | |
Motor starter type | Direct on-line contactor |
Contactor coil voltage | 220 V AC standard |
standards | EN 60947-4-1 |
IEC 60947-1 | |
EN 60947-1 | |
JIS C8201-4-1 | |
IEC 60947-4-1 | |
product certifications | CSA |
CB | |
RMRoS | |
ABS | |
LROS (Lloyds register of shipping) | |
UL | |
RINA | |
BV | |
DNV | |
UKCA | |
Compatibility code | LC1F |
Control circuit type | AC at 40...400 Hz |
Environment | |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 |
IP20 front face with shrouds conforming to VDE 0106 | |
Protective treatment | TH |
Ambient air temperature for operation | -5…55 °C |
Ambient air temperature for storage | -60…80 °C |
Permissible ambient air temperature around the device | -40…70 °C |
height | 238 mm |
Width | 233 mm |
Depth | 232 mm |