Time-Delay Auxiliary Contact Block, TeSys D, 1NO + 1NC, On-Delay 1-30s, Front Mounting, Screw Terminals, Schneider Electric

In stock
SKU
LADS2
Special Price EGP 3,134 Regular Price EGP 5,804

Details

The LADS2 Time-Delay Auxiliary Contact Block, a component of Schneider Electric's TeSys D product line, is a valuable addition to your electrical control system. This contact block is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) contact, featuring an adjustable on-delay time range of 1 to 30 seconds. Its front-mounting design and screw terminals make installation and wiring simple and efficient, ensuring precise control in your applications.

 

Key Features:

Dual Contacts: The LADS2 provides both 1 Normally Open (NO) and 1 Normally Closed (NC) contacts, offering flexibility in your control circuit design.

Adjustable On-Delay: With an adjustable on-delay time range of 1 to 30 seconds, you can fine-tune the timing for your specific application needs.

Front Mounting: The front-mounting design facilitates easy installation and maintenance, allowing for quick access and adjustments.

Screw Terminals: Screw terminals simplify the wiring process, ensuring a secure and reliable connection.

 

Technical Specifications:

Contact Configuration: 1NO (Normally Open) + 1NC (Normally Closed)

Delay Time Range: On-Delay, 1-30 seconds

Mounting: Front Mounting

Terminals: Screw Terminals

 

Specifications  

Main

 
Range TeSys
  TeSys Deca
Product name TeSys Deca
Product or component type Time delay auxiliary contact block
Range compatibility TeSys Deca CAD
  TeSys Deca LC1D
  TeSys F LC1F
  TeSys F CR1F
Device application Star delta starter
Mounting location Front
Pole contact composition 1 NO + 1 NC
Contacts operation Time delay
Timer type On delay
Time delay range 1...30 s
[Ue] rated operational voltage 690 V AC 25...400 Hz
[Ie] rated operational current 6 A at 120 V AC-15
  1.04 A at 690 V AC-15
  0.55 A at 125 V DC-13
  0.1 A at 600 V DC-13
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
  600 V conforming to UL 60947-5-1
  600 V conforming to CSA C22.2 No 60947-5-1
[Ith] conventional free air thermal current 10 A (at 60 °C)
standards CSA C22.2 No 60947-5-1
  GB/T 14048.5
  EN/IEC 60947-5-1
product certifications IECEE CB Scheme
  UL
  CSA
  CCC
  EAC
  UKCA
Complementary  
Irms rated making capacity 140 A at <= 690 V AC conforming to IEC 60947-5-1
  250 A at <= 690 V DC conforming to IEC 60947-5-1
Permissible short-time rating 100 A 60 °C 1 s
  120 A 60 °C 500 ms
  140 A 60 °C 100 ms
Protection type GG fuse 10 A
Mechanical durability 5 Mcycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
  1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance > 10 MOhm
Connections - terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
  Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
  Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
  Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
  Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid
  Screw clamp terminals 2 cable(s) 1…2.5 mm²rigid
  Screw clamp terminals
Tightening torque 1.7 N.m - with screwdriver flat Ø 6 mm
  1.7 N.m - with screwdriver Philips No 2
  1.7 N.m - with screwdriver pozidriv No 2
height 48 mm
Width 44 mm
Depth 61 mm
Colour Dark grey
Environment  
Environmental characteristic Normal environment
IP degree of protection IP20 conforming to IEC 60529
Protective treatment TH conforming to IEC 60068
Ambient air temperature for storage -60…80 °C

 

More Information

More Information
Brand Schneider Electric
Depth [cm] 6.1
Width [cm] 4.4
Height [cm] 4.8

Reviews

You're reviewing:

Time-Delay Auxiliary Contact Block, TeSys D, 1NO + 1NC, On-Delay 1-30s, Front Mounting, Screw Terminals, Schneider Electric