Product or component type: Circuit breaker
Device application: Distribution
Number of poles: 3P

The Schneider Electric C25N32D160 is a high-quality circuit breaker designed for robust performance and protection in a range of electrical applications. With a current rating of 160A and three poles, it's built to ensure the safe and reliable operation of your electrical circuits.

 

Key Features:

High Performance: This circuit breaker is part of the Compact NSX range, known for its high performance and reliable protection. It's designed to handle heavy electrical loads and provide exceptional performance in demanding environments.

Robust Construction: Schneider Electric products are known for their durability, and the C25N32D160 is no exception. It's built to last and withstand the test of time, ensuring that your electrical systems stay protected.

Micrologic 2.2 Trip Unit: The Micrologic trip unit ensures precise and adjustable protection settings, enhancing the safety of your electrical installation.

Multiple Applications: This circuit breaker is suitable for a wide range of applications, making it a versatile choice for your electrical protection needs.

 

Whether you need reliable circuit protection in an industrial setting or for commercial applications, the Schneider Electric C25N32D160 is a dependable choice.

 

Specifications 

Main

 
RangeComPacT new generation
Product nameComPacT NSX new generation
device short nameNSX250N
Product or component typeCircuit breaker
Device applicationDistribution
Poles description3P
Protected poles description3D
[In] rated current160 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
 15 kA at 600 V AC 50/60 Hz conforming to UL 508
Performance levelN 50 kA 415 V AC
Trip unit nameMicroLogic 2.2
Trip unit technologyElectronic
Trip unit protection functionsLSoI
control typeToggle
Circuit breaker mounting modeFixed
Complementary 
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles at 440 V In/2
 10000 cycles at 440 V In
 10000 cycles at 690 V In/2
 5000 cycles at 690 V In
Power dissipation per pole7.17 W
mounting supportBackplate
Mounting positionHorizontal and vertical
 Flat on the back
Upside connectionFront
downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (long time)
 So : for short time short-circuit protection with fixed delay
 I : for instantaneous short-circuit protection
Trip unit rating160 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range63...160 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range400 s at 1.5 x Ir
 16 s at 6 x Ir
 11 s at 7.2 x Ir
thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range1.5...10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range2400 A
earth-leakage protectionWithout
Zone selective interlocking ZSIWithout
Number of slots for electrical auxiliaries5 slot(s)
Local signallingFlashing LED (green) for ready to operate
 LED 105 % Ir (red) for overload
 LED 90 % Ir (orange) for overload
Width (W)105 mm
Height (H)161 mm
Depth (D)86 mm
Net weight2.4 kg
Environment 