Acti9 iK60N Miniature Circuit Breaker 1P, 32 A, C curve (A9K24132)
Poles description: 1P
Number of protected poles: 1
[In] rated current: 32 A at 30 °C
Breaking capacity: 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
When it comes to safeguarding your electrical circuits, trust in Schneider Electric's Acti9 iK60N Miniature Circuit Breaker. This 1-pole circuit breaker is designed to provide you with the utmost reliability and safety for your electrical installations.
Key Features:
-
1-Pole Design: With a single pole, it offers reliable protection for individual circuits.
-
High Amperage Rating: Suitable for handling various electrical loads with efficiency.
-
C-Curve: Designed to respond quickly during short circuit situations, enhancing safety.
-
Impressive Breaking Capacity: With a substantial breaking capacity, it effectively handles fault currents.
-
User-Friendly: Easy to install and operate, making it an ideal choice for various applications.
-
Durable Build: Crafted to be long-lasting, ensuring the longevity and reliability of your electrical system.
The Schneider Electric Acti9 iK60N Miniature Circuit Breaker is tailored to meet your circuit protection needs, providing peace of mind and uninterrupted electrical performance. Whether for residential or industrial use, its impressive specifications and robust design make it the perfect choice.
Elevate the safety and reliability of your electrical circuits with the Schneider Electric Acti9 iK60N Miniature Circuit Breaker – your trusted circuit guardian!
Specifications | |
Main | |
Device application | Distribution |
Range | Acti9 |
Product name | Acti9 iK60 |
Product or component type | Miniature circuit-breaker |
Device short name | iK60N |
Poles description | 1P |
Number of protected poles | 1 |
[In] rated current | 32 A at 30 °C |
Network type | AC |
Trip unit technology | Thermal-magnetic |
Curve code | C |
Breaking capacity | 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
Suitability for isolation | Yes conforming to EN/IEC 60898-1 |
standards | EN/IEC 60898-1 |
Complementary | |
Network frequency | 50/60 Hz |
Magnetic tripping limit | 5...10 x In |
[Ics] rated service breaking capacity | 6000 A 100 % conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz |
Limitation class | 3 conforming to EN/IEC 60898-1 |
[Ui] rated insulation voltage | 440 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
[Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60898-1 |
Contact position indicator | No |
control type | Toggle |
Local signalling | ON/OFF indication |
Mounting mode | Clip-on |
mounting support | DIN rail |
9 mm pitches | 2 |
height | 85 mm |
Width | 18 mm |
Depth | 78.5 mm |
Net weight | 100 g |
Colour | White |
Mechanical durability | 20000 cycles |
Electrical durability | 10000 cycles |
Locking options description | Padlocking device |
Connections - terminals | Tunnel type terminal (top or bottom) 1…25 mm² rigid |
Tunnel type terminal (top or bottom) 1…16 mm² flexible | |
Wire stripping length | 14 mm for top or bottom connection |
Tightening torque | 2 N.m top or bottom |
earth-leakage protection | Without |
Environment | |
IP degree of protection | IP20 conforming to IEC 60529 |
Pollution degree | 2 conforming to EN/IEC 60898-1 |
Overvoltage category | III |
Ambient air temperature for operation | -25…60 °C |
Ambient air temperature for storage | -40…85 °C |
Brand | Schneider Electric |
---|---|
Depth [cm] | 7.85 |
Width [cm] | 1.8 |
Height [cm] | 8.5 |