Schneider Electric Tesys-F Contactor, 3P, 3-NO, AC3, 440V, 630A, 220V AC Coil
Range of product: TeSys
Product type: Contactor
Poles: 3P
Contactor application: Resistive load, Motor control
The Schneider Electric LC1F630M7 TeSys F Contactor is a high-capacity switching device designed for controlling electric motors and power circuits. With three poles, three normally open (NO) contacts, and a 630 A AC3 rated current at 440 V, it offers robust and reliable performance for a wide range of industrial applications. The 220 V AC coil ensures efficient and precise operation.
Key Features:
High-Performance Contactors: Schneider Electric's LC1F630M7 TeSys F Contactor is built to handle heavy-duty tasks, making it suitable for demanding industrial environments.
Three Normally Open Contacts: This contactor provides three NO contacts, enhancing its versatility in controlling motors and equipment.
Robust and Reliable: Schneider Electric is known for producing high-quality and dependable electrical components, ensuring the longevity and efficiency of this contactor.
Wide Range of Applications: The 630 A AC3 rated current makes it suitable for various industrial settings.
Technical Specifications:
Pole Configuration: 3P (Three Poles)
Rated Current AC3: 630 A
Rated Operational Voltage AC3: 440 V
Coil Voltage: 220 V AC
Specifications | |
Main | |
Range | TeSys |
Range of product | TeSys F |
Product or component type | Contactor |
device short name | LC1F |
contactor application | Resistive load |
Motor control | |
utilisation category | AC-3 |
AC-1 | |
AC-4 | |
Poles description | 3P |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz |
<= 460 V DC | |
[Uc] control circuit voltage | 220 V AC 40...400 Hz |
[Ie] rated operational current | 1000 A (at <40 °C) at <= 440 V AC AC-1 |
630 A (at <55 °C) at <= 440 V AC AC-3 | |
Complementary | |
[Uimp] rated impulse withstand voltage | 8 kV |
[Ith] conventional free air thermal current | 1000 A (at 40 °C) |
1250 A | |
Rated breaking capacity | 5040 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 5050 A 40 °C - 10 s |
4400 A 40 °C - 30 s | |
3400 A 40 °C - 1 min | |
2200 A 40 °C - 3 min | |
1600 A 40 °C - 10 min | |
Associated fuse rating | 1000 A gG at <= 440 V |
630 A aM at <= 440 V | |
Average impedance | 0.12 mOhm - Ith 1000 A 50 Hz |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 |
1500 V conforming to VDE 0110 group C | |
Power dissipation per pole | 120 W AC-1 |
48 W AC-3 | |
Overvoltage category | III |
Control circuit voltage limits | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) |
Drop-out: 0.25...0.5 Uc 40...400 Hz (at 55 °C) | |
Mechanical durability | 5 Mcycles |
Inrush power in VA | 1650 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
Hold-in power consumption in VA | 22 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
Maximum operating rate | 1200 cyc/h 55 °C |
Operating time | 40...80 ms closing |
100...200 ms opening | |
Connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end |
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end | |
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end | |
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end | |
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end | |
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end | |
Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm | |
Power circuit: bolted connection | |
Tightening torque | Control circuit: 1.2 N.m |
Power circuit: 58 N.m | |
mounting support | Plate |
Heat dissipation | 20 W |
motor power range | 250…500 kW at 380…440 V 3 phases |
110…220 kW at 200…240 V 3 phases | |
250…500 kW at 480…500 V 3 phases | |
Motor starter type | Direct on-line contactor |
Contactor coil voltage | 220 V AC standard |
standards | EN 60947-1 |
IEC 60947-4-1 | |
JIS C8201-4-1 | |
IEC 60947-1 | |
EN 60947-4-1 | |
product certifications | LROS (Lloyds register of shipping) |
CB | |
UL | |
RMRoS | |
CSA | |
ABS | |
BV | |
DNV | |
RINA | |
UKCA | |
Compatibility code | LC1F |
Control circuit type | AC at 40...400 Hz |
Environment | |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 |
IP20 front face with shrouds conforming to VDE 0106 | |
Protective treatment | TH |
Ambient air temperature for operation | -5…55 °C |
Ambient air temperature for storage | -60…80 °C |
Permissible ambient air temperature around the device | -40…70 °C |
height | 304 mm |
Width | 309 mm |
Depth | 255 mm |
Operating altitude | 3000 m without derating |
Net weight | 18.6 kg |
Brand | Schneider Electric |
---|---|
Depth [cm] | 25.5 |
Width [cm] | 18.6 |
Height [cm] | 30.4 |